Crossref Cited-by Linking logo

Collect. Czech. Chem. Commun. 1969, 34, 1375-1386
https://doi.org/10.1135/cccc19691375

Radiochemical study of the sorption of trace elements. V. Adsorption and desorption of bivalent mercury on polyethylene

P. Beneš and I. Rajman

Crossref Cited-by Linking

  • Xiang Yuping, Guo Yingying, Liu Guangliang, Liu Yanwei, Song Maoyong, Shi Jianbo, Hu Ligang, Yin Yongguang, Cai Yong, Jiang Guibin: Particle-Bound Hg(II) is Available for Microbial Uptake as Revealed by a Whole-Cell Biosensor. Environ. Sci. Technol. 2022, 56, 6754. <https://doi.org/10.1021/acs.est.1c08946>
  • Yu Li-Ping, Yan Xiu-Ping: Factors affecting the stability of inorganic and methylmercury during sample storage. TrAC Trends in Analytical Chemistry 2003, 22, 245. <https://doi.org/10.1016/S0165-9936(03)00407-2>
  • Kolics A., Varga K., Maleczki E., Horányi G.: Investigation of cobalt sorption on polyethylene using an in situ radioactive tracer method. Journal of Radioanalytical and Nuclear Chemistry, Articles 1993, 170, 457. <https://doi.org/10.1007/BF02041481>
  • Yang X. G., Jackwerth E.: Untersuchungen zur adsorptiven anreicherung von elementspuren an adsorberharzen. Z. Anal. Chem. 1989, 335, 712. <https://doi.org/10.1007/BF01204075>
  • Shimomura Shigeru: Analytical Behavior and Some Physical Properties of Mercury A Review. ANAL. SCI. 1989, 5, 633. <https://doi.org/10.2116/analsci.5.633>
  • Krivan V., Haas H. F.: Prevention of loss of mercury(II) during storage of dilute solutions in various containers. Z. Anal. Chem. 1988, 332, 1. <https://doi.org/10.1007/BF00487020>
  • Tokunaga Shuzo: Some Observations on the Loss of Mercury from Aqueous Solutions. ANAL. SCI. 1986, 2, 89. <https://doi.org/10.2116/analsci.2.89>
  • Heiden R. W., Aikens D. A.: Humic acid as a preservative for trace mercury(II) solutions stored in polyolefin containers. Anal. Chem. 1983, 55, 2327. <https://doi.org/10.1021/ac00264a029>
  • Röder E., Pütz W., Frisse R.: Bestimmung von Au, Fe, Zn und Hg in homöopathischen Dilutionen durch zerstörungsfreie Neutronenaktivierungsanalyse. Z. Anal. Chem. 1981, 307, 120. <https://doi.org/10.1007/BF00487491>
  • Clanet Frank, Deloncle Roger, Popoff Georges: Capteur de resine chelatante pour le prelevement la preconcentration et la determination de metaux traces toxiques (Zn, Cd, Hg, Pb) dans les eaux. Water Research 1981, 15, 591. <https://doi.org/10.1016/0043-1354(81)90022-1>
  • Massee R., Maessen F.J.M.J., De goeij J.J.M.: Losses of silver, arsenic, cadmium, selenium and zinc traces from distilled water and artificial sea-water by sorption on various container surfaces. Analytica Chimica Acta 1981, 127, 181. <https://doi.org/10.1016/S0003-2670(01)83974-X>
  • Subramanian K. S., Chakrabarti C. L., Sueiras J. E., Maines I. S.: Preservation of some trace metals in samples of natural waters. Anal. Chem. 1978, 50, 444. <https://doi.org/10.1021/ac50025a022>
  • Wheeler S. R., Hamdy M. K.: Removal of soluble mercury from water by rubber. Bull. Environ. Contam. Toxicol. 1977, 17, 150. <https://doi.org/10.1007/BF01685542>
  • Żmijewska W.: Activation analysis of mercury in environmental samples. J. Radioanal. Chem. 1977, 35, 389. <https://doi.org/10.1007/BF02518017>
  • Batley G.E., Gardner D.: Sampling and storage of natural waters for trace metal analysis. Water Research 1977, 11, 745. <https://doi.org/10.1016/0043-1354(77)90042-2>
  • Gladney Ernest S., Goode William E.: Loss of tin from aqueous solutions during storage. Analytica Chimica Acta 1977, 91, 411. <https://doi.org/10.1016/S0003-2670(01)93696-7>
  • Unger Brian C., Green Vernon A.: Blood Lead Analysis–Lead Loss to Storage Containers. Clinical Toxicology 1977, 11, 237. <https://doi.org/10.3109/15563657708989836>
  • Gladney E.S., Apt K.E.: Loss of iridium, osmium and ruthenium from aqueous solutions during storage. Analytica Chimica Acta 1976, 85, 393. <https://doi.org/10.1016/S0003-2670(01)84705-X>
  • Ure A.M.: The determination of mercury by non-flame atomic absorption and fluorescence spectrometry. Analytica Chimica Acta 1975, 76, 1. <https://doi.org/10.1016/S0003-2670(01)81980-2>
  • Watling R.J.: The determination of mercury at picogram/litre levels in water with a microwave-induced argon plasma emission system. Analytica Chimica Acta 1975, 75, 281. <https://doi.org/10.1016/S0003-2670(01)85352-6>
  • Lo J. M., Wai C. M.: Mercury loss from water during storage. Mechanisms and prevention. Anal. Chem. 1975, 47, 1869. <https://doi.org/10.1021/ac60361a003>
  • Thabet S. K., Adrouni S. M., Tayim H. A.: 2,2'-[2,6-Pyridinediylbis(methylidynenitrilo)]diphenol. Highly selective reagent for the detection of uranium(VI), antimony(III), and bismuth(III). Anal. Chem. 1975, 47, 1870. <https://doi.org/10.1021/ac60361a018>
  • Beneš P., Paulenová M.: Surface charge and adsorption properties of polyethylene in aqueous solutions of inorganic electrolytes. Colloid Polymer Sci 1974, 252, 472. <https://doi.org/10.1007/BF01554753>
  • Mac Naughton M.G, James R.O: Adsorption of aqueous mercury (II) complexes at the oxide/water interface. Journal of Colloid and Interface Science 1974, 47, 431. <https://doi.org/10.1016/0021-9797(74)90275-6>
  • Shendrikar A.D., West P.W.: A study of adsorption characteristics of traces of chromium(III) and (VI) on selected surfaces. Analytica Chimica Acta 1974, 72, 91. <https://doi.org/10.1016/S0003-2670(01)82952-4>
  • King W. G., Rodriguez J. M., Wai C. M.: Losses of trace concentrations of cadmium from aqueous solution during storage in glass containers. Anal. Chem. 1974, 46, 771. <https://doi.org/10.1021/ac60342a024>
  • Rajagopalan Indira., Rajagopalan S. R.: Polarographic method for the determination of hexafluorosilicate. Anal. Chem. 1974, 46, 769. <https://doi.org/10.1021/ac60342a038>
  • Issaq Haleem J., Zielinski Walter L.: Loss of lead from aqueous solutions during storage. Anal. Chem. 1974, 46, 1328. <https://doi.org/10.1021/ac60345a015>
  • Chadwick Thomas C.: Gravimetric determination of gold and platinum using 2,4,6-triphenylpyrylium chloride. Anal. Chem. 1974, 46, 1326. <https://doi.org/10.1021/ac60345a017>
  • Rosain R.M., Wai C.M.: The rate of loss of mercury from aqueous solution when stored in various containers. Analytica Chimica Acta 1973, 65, 279. <https://doi.org/10.1016/S0003-2670(01)82493-4>
  • Evans J. M.: Sorption of Iodine onto Corona-Modified Polyethylene. The Journal of Adhesion 1973, 5, 29. <https://doi.org/10.1080/00218467308078436>
  • Krenkel P. A., Goldwater L.: Mercury: Environmental considerations, part I. C R C Critical Reviews in Environmental Control 1973, 3, 303. <https://doi.org/10.1080/10643387309381605>