Collect. Czech. Chem. Commun.
1983, 48, 2446-2453
https://doi.org/10.1135/cccc19832446
Isothermal and isobaric vapour-liquid equilibrium data in the tetrachloromethane-sec-butyl alcohol system
Jan Linek
Institute of Chemical Process Fundamentals, Czechoslovak Academy of Sciences, 165 02 Prague 6-Suchdol
Abstract
Isothermal vapour-liquid equilibrium data at 65, 73 and 80 °C and isobaric ones at 101.3 kPa were measured in the tetrachloromethane-sec-butyl alcohol system. A modified circulation still of the Gillespie type was used for the measurements. Under the conditions of measurement, the system exhibits positive deviations from Raoult's law and minimum boiling-point azeotropes. The experimental data were fitted to a number of correlation equations, the most suitable being the Wilson equation.