Collect. Czech. Chem. Commun.
1986, 51, 1222-1239
https://doi.org/10.1135/cccc19861222
Theoretical analysis of counter-current absorption of a poorly soluble gas based on the PDE-AD model
Pavel Moravec and Vladimír Staněk
Institute of Chemical Process Fundamentals, Czechoslovak Academy of Sciences, 165 02 Prague 6-Suchdol
Abstract
Expression have been derived in the paper for all four possible transfer functions between the inlet and the outlet gas and liquid steams under the counter-current absorption of a poorly soluble gas in a packed bed column. The transfer functions have been derived for the axially dispersed model with stagnant zone in the liquid phase and the axially dispersed model for the gas phase with interfacial transport of a gaseous component (PDE - AD). calculations with practical values of parameters suggest that only two of these transfer functions are applicable for experimental data evaluation.